S LED Wall CalculatorAV by Dave planning tools

Video engineering · field planning

LED wall calculator

Plan a build from actual cabinet dimensions and pixel counts. Compare wall raster with content, estimate processor ports and electrical demand, and carry the result into Power Load.

  • Cabinet aware
  • Live build map
  • Saved profiles
Quick calculators
Saved

Advanced planning suite · cabinet aware

LED Wall Configurator

Turn an LED cabinet profile and deployment goal into buildable geometry, native raster, content-fit guidance, NovaStar port estimates, viewing distance, and separated typical and maximum power plans.

Product / Cabinet Profile

When both raster fields are entered, they are authoritative and pitch is a validation check. Leave both blank to derive cabinet pixels from dimensions ÷ pitch.

Layout

Cabinet layout uses the entered whole-cabinet array directly.

Video / NovaStar Port Planner
LED Power Planner / Viewing Distance
5 cabinets high 8 cabinets wide

Live cabinet map

8 × 5

1,376 × 860 native canvas
4.00 × 2.50 m build

Port load61%
ViewerReview
Wall 0 × 0 ft 0 × 0 m
Native Raster 0 × 0 px 0 MP · 0:1
Content Fit Review 1920 × 1080 source
NovaStar Planning 0 data ports Planning estimate
Power 0 kW max 0 kW typical
Geometry Details
Build Array0 × 0 cabinets
Cabinet Count0
Metric Size0 × 0 m
Imperial Size0 × 0
Screen Area0 m² · 0 ft²
Diagonal0 m · 0 ft
Effective Cabinet Raster0 × 0 px
Pitch-Derived Check0 × 0 px
Implied Pitch W / H0 × 0 mm

The entered cabinet layout is used directly.

Content Fit
Source → Wall0 × 0 → 0 × 0
Scale X / Y0 × / 0 ×
Active Wall Use0%
Aspect Difference0%
Suggested Canvas0 × 0 px
Source Bandwidth0 Gbps

Native wall raster is the first-choice content canvas.

Processing / Data
Safe Pixels / Port0
Average Port Load0
Port Utilization0%
Wall Payload0 Gbps

Processor output capacity is separate from production-network bandwidth and must be confirmed against the selected processor and receiver cards.

Power / Viewing / Assumptions
Maximum Load0 kW · 0 A
Typical Load0 kW · 0 A
Planning Circuits0 max · 0 typical
Product Home RunsNot specified
Viewing Range0–0 ft
Audience CheckReview
  • Enter a cabinet profile to review planning assumptions.

Planning estimates only: Verify final cabinet, receiver-card, processor, signal, and power specifications against the actual product documentation. Confirm electrical distribution with the venue and a qualified person; the calculator does not establish code compliance or a verified safe load.