S AV Calculator System by Dave AV tools

Field math

AV calculator

Fast operator checks for delay, projection, record storage, power, and cabinet-aware LED wall planning. Values update as you type and the page remembers the last setup in this browser.

  • 6 quick calculators
  • LED wall suite
  • Instant updates

Audio Delay

Distance to delay
Delay0 ms
Frames0 fr
48k Samples0
Enter speaker distance to calculate delay time.

Projection

Screen and throw
Height0 ft
Diagonal0 in
Ideal Throw0 ft
Use actual distance to compare against the lens throw ratio.

Record Storage

Bitrate to drive size
Base Size0 GB
With Headroom0 GB
Per Hour0 GB
Use camera bitrate, feed count, and runtime to size recording media.

Power Load

Nameplate current
Per Device Current
Total Nameplate
Of 80% Planning Reference
Planning reference: Enter the equipment nameplate current. Include startup or inrush demand and verify the distribution before assigning circuits.

Voltage Drop

Cable run loss
Drop0 V
Percent0%
End Volts0 V
Keep drop under 3 percent for sensitive gear; under 5 percent overall.

SPL Distance

Inverse square loss
SPL At Target0 dB
Loss0 dB
Doublings0
Free-field estimate. Real rooms add reflections and gain.

Advanced planning suite · cabinet aware

LED Wall Configurator

Turn an LED cabinet profile and deployment goal into buildable geometry, native raster, content-fit guidance, NovaStar port estimates, viewing distance, and separated typical and maximum power plans.

Product / Cabinet Profile

When both raster fields are entered, they are authoritative and pitch is a validation check. Leave both blank to derive cabinet pixels from dimensions ÷ pitch.

Layout

Cabinet layout uses the entered whole-cabinet array directly.

Video / NovaStar Port Planner
LED Power Planner / Viewing Distance
5 cabinets high 8 cabinets wide

Live cabinet map

8 × 5

1,376 × 860 native canvas
4.00 × 2.50 m build

Port load61%
ViewerReview
Wall 0 × 0 ft 0 × 0 m
Native Raster 0 × 0 px 0 MP · 0:1
Content Fit Review 1920 × 1080 source
NovaStar Planning 0 data ports Planning estimate
Power 0 kW max 0 kW typical
Geometry Details
Build Array0 × 0 cabinets
Cabinet Count0
Metric Size0 × 0 m
Imperial Size0 × 0
Screen Area0 m² · 0 ft²
Diagonal0 m · 0 ft
Effective Cabinet Raster0 × 0 px
Pitch-Derived Check0 × 0 px
Implied Pitch W / H0 × 0 mm

The entered cabinet layout is used directly.

Content Fit
Source → Wall0 × 0 → 0 × 0
Scale X / Y0 × / 0 ×
Active Wall Use0%
Aspect Difference0%
Suggested Canvas0 × 0 px
Source Bandwidth0 Gbps

Native wall raster is the first-choice content canvas.

Processing / Data
Safe Pixels / Port0
Average Port Load0
Port Utilization0%
Wall Payload0 Gbps

Processor output capacity is separate from production-network bandwidth and must be confirmed against the selected processor and receiver cards.

Power / Viewing / Assumptions
Maximum Load0 kW · 0 A
Typical Load0 kW · 0 A
Planning Circuits0 max · 0 typical
Product Home RunsNot specified
Viewing Range0–0 ft
Audience CheckReview
  • Enter a cabinet profile to review planning assumptions.

Planning estimates only: Verify final cabinet, receiver-card, processor, signal, and power specifications against the actual product documentation. Confirm electrical distribution with the venue and a qualified person; the calculator does not establish code compliance or a verified safe load.

Operator Summary

Saved

        
Field verification required: confirm every result against equipment specifications and venue conditions before show use. Calculator output does not verify electrical safety or suitability.